HEINZMANN Company Group

HEINZMANN
Engine & Turbine Management

HEINZMANN Electric Drives
Robust electric motors

HEINZMANN China
Control & Actuation

HEINZMANN Automation
Marine Automation

HEINZMANN UK
Gas & Water Turbine Control

HEINZMANN Australia
Steam Turbine Control

CPK Automotive
Emission Control

Giro Engineering
Diesel Engine Components

HEINZMANN IFT GmbH
Oil Mist Separators and Blow-by Filter Technology

REGULATEURS EUROPA

Technologies empowering efficiency

The signal converter modules below provide an interface between the REGULATEURS EUROPA range hydraulic actuators and also some of the HEINZMANN range of electric actuators and electronic control units from other manufactures. The modules are designed for DIN rail mounting.

loading...
Converter Module ECM7118
Converter Module 7150

Converter Module ECM7118

Actuator Drive Signal Converter Module. Interface to any electronic control unit from any other manufacturer.

Main Features:

  • Size: 75 mm x 110 mm x 50 mm
  • Mounting: Standard DIN rail mounting
  • Power supply: 24 VDC (18 ... 32 V) max. 2 A
  • Input: Selectable 0 ... 200 mA or 4 ... 20 mA. The input signal is isolated from both power supply and output signal.
  • Input resistance: 35 Ω for 0 ... 200 mA input, 235 Ω for 4 ... 20 mA input
  • Output: Pre-set for RE series actuators, or 0-1000 mA nominal
  • Time lag: < 5 mSec. for 100 % step
  • Ambient temperature: -10 ... +75 °C
  • EMC requirements: In order to comply with the requirements of IEC61000-4-2, -3, -4 and -5 the module must be mounted in a steel plate enclosure
  • Type approval

 

More information

Data Sheet

Technical Drawing

>> Certificate

Converter Module 7150

Actuator Drive Signal Converter Module. Interface to any electronic control unit from any other manufacturer.

Signal converter module to interface Woodward electronic speed governors (2301A, 721, 723, etc.) to HEINZMANN actuators

Main Features:

  • Input signal: 0 ... 200mA range (35 Ohm nominal input resistance)
  • Output signal: 4 ... 20mA range (adjustable)
  • Fault sensing:
      • 4 ... 20mA output signal wire-break detection. 0 ... 200 mA input signal is broken when output signal wire break is detected
      • Module health status (4 ... 20mA wire break/loss of power supply) indicated via clean contact and LED.
  • Response: <5 ms for 100 % step change
  • Power supply: 24 VDC nominal (18 ... 32 VDC range)
  • Isolation: 1 kV between input, output, and power supply
  • Temperature: -20 ... 70 oC operating range
  • Size: [to follow]
  • Mounting: standard DIN rail module