HEINZMANN Company Group

HEINZMANN
Engine & Turbine Management

HEINZMANN Electric Drives
Robust electric motors

HEINZMANN China
Control & Actuation

HEINZMANN Automation
Marine Automation

HEINZMANN UK
Gas & Water Turbine Control

HEINZMANN Australia
Steam Turbine Control

CPK Automotive
Emission Control

Giro Engineering
Diesel Engine Components

HEINZMANN IFT GmbH
Oil Mist Separators and Blow-by Filter Technology

REGULATEURS EUROPA

Thinking in control & monitoring

analogue input analogue output digital input digital output inductive
or Hall pick-up
RS-232/
RS-485
CAN
8x isolated,
each channel selectable
0...20 mA
4...20 mA
0...5 V
0...10 V
8x isolated,
each channel selectable
0...20 mA
4...20 mA
0...5 V
0...10 V
16x binary 8x relay
8x opto
2x 2x isolated 3x isolated
loading...
Generator Panels
Viking35 Generator Control Panel

Generator Panels

The typical panel shown includes all of the necessary I/O to interface with the engine, generator and ships systems. The Windows based PC software provides an easy interface with the generator control panel; allowing performance to be monitored and parameters changed by authorised personnel.

Control and monitoring panels for specialized applications

Specialised applications such as front-line military vessels require hardware designed to withstand the adverse environment. REGULATEURS EUROPA is experienced in the design and manufacture of integrated control and monitoring panels designed to perform in ships where vibration and shock etc are a major factor.

Viking35 Generator Control Panel

At the heart of many generator control panels is the Viking35 ECU which combines the engine management functions together with multi engine electrical and/or mechanical load sharing, via load measure transducers.

Technical data

  • Power supply: 24 VDC
  • Degree of protection: IP00

Engine Types & Applications

Generators
loading...
Overview
MA-01
MA-02
MA-03
PS-01
PS-02
AI-01
AI-02
AI-03
AI-04
AO-01
DI-01
DO-02
DO-03
TB-01
TB-02

ICENI Distributed I/O System

ICENI Distributed I/O System

  • Open protocols to PLCs, PCs etc.
  • Extended temperature range (-20 ... +70 °C)
  • Inbuilt user interface for commissioning and support
  • Robust construction
  • Independent electrical isolation
  • Redundant power supply capability
  • “Plug and Play” automatic configuration
  • Cost-effective solution for a wide range of applications

 

More information

Data Sheet

Master Module ICENI/MA-01

The module enables the ICENI distributed system to be connected as a slave node onto an RS-485 Modbus RTU network.

Technical data

  • Max no. of I/O modules: 16
  • General: Modbus RTU

More information

Data Sheet

Manual

Master Module ICENI/MA-02

The module enables the ICENI distributed system to be connected as a slave node onto a CANopen network.

Technical data

  • Max no. of I/O modules:: 16
  • General: CANopen

More information

Data Sheet

Manual

Master Module ICENI/MA-03

The module enables the ICENI distributed system to be connected as a slave node onto a DeviceNet network.

Technical data

  • Max no. of I/O modules:  
  • General: DeviceNet

More information

Data Sheet

Manual

Power Supply Module ICENI/PS-01

The module provides a stabilised supply for the distributed system.

Technical data

  • Max no. of I/O modules: 16 [subject to unit consumption]
  • General: Single operation

More information

Data Sheet

Manual

Power Supply Module ICENI/PS-02

This module provides a redundant stabilised supply for the distributed system.

Technical data

  • Max no. of I/O modules: 16 [subject to unit consumption]
  • General: Redundant supply operation

More information

Data Sheet

Manual

Analogue Input Module ICENI/AI-01

The module provides four, individually isolated input channels, for monitoring field sensors [pressure, level, position, etc.].

Technical data

  • Number of inputs: 4 inputs, individually isolated
  • General: 4 channel, 4-20 mA

More information

Data Sheet

Manual

Analogue Input Modulee ICENI/AI-02

The module provides four, individually isolated input channels, for monitoring field voltage sensors [level, position, etc.].

Technical data

  • Number of inputs: 4 inputs, individually isolated
  • General: 4 channel, 0 - 10 VDC

More information

Data Sheet

Manual

Analogue Input Module ICENI/AI-03

The module provides four isolated input channels for monitoring high field temperature sensors [exhaust, boiler, flare, etc.].

Technical data

  • Number of inputs: 4 inputs
  • General: 4 channel, thermocouple

More information

Data Sheet

Manual

Analogue Input Module ICENI/AI-04

The module provides four isolated input channels for monitoring field temperature sensors [fluids, bearings, motor windings, etc.].

Technical data

  • Number of inputs: 4 inputs
  • General: 4 channel, RTD

More information

Data Sheet

Manual

Analogue Output Module ICENI/AO-01

The module provides four loop powered, individually isolated output channels, for interfacing to field devices [panel meters, control valves, actuators, etc.].

Technical data

  • Number of outputs: 4 individually isolated outputs
  • General: 4 channel, 4-20 mA

More information

Data Sheet

Manual

Digital Input Module ICENI/DI-01

The module provides eight, individually powered, digital input channels for monitoring field devices [position switches, level sensors, operator inputs, etc.].

Technical data

  • Number of inputs: 8 individually isolated inputs
  • General: 8 channel, 24 VDC

More information

Data Sheet

Manual

Digital Output Module ICENI/DO-02

The module provides eight, individually isolated, electronically switched output channels, for controlling field devices [indicators, actuators, audible alarms, etc.].

Technical data

  • Number of outputs: 8, individually isolated outputs
  • General: 8 channel, 24 VDC

More information

Data Sheet

Manual

Digital Output Module ICENI/DO-03

The module provides four switched relay output channels for controlling field devices [indicators, actuators, audible alarms, etc.].

Technical data

  • Number of outputs: 4 changeover contacts
  • General: 4 channel, relay output

More information

Data Sheet

Manual

Terminal Block Type 1 Module ICENI/TB-01

The module provides eight independent signal pathways routed from one side of the module to the other. It can assist to simplify the routing of field wiring.

Technical data

  • Number of inputs: 8 signal paths

More information

Data Sheet

Manual

Terminal Block Type 2 Module ICENI/TB-02

The module provides two signal pathways each with four interlinked terminals routed from one side of the module to the other. It can assist to simplify the routing of field wiring.

Technical data

  • Number of inputs: 2 signal paths

More information

Data Sheet

Manual